Slide Wall

Our Products

For Products of building aggregates, LCK can offer such core crushing machines like jaw crusher, impact crusher, cone crusher and sand-making machine. So far, we have developed 10 series which include over 100 machine models that can be matched freely so as to meet various demands on yielding and types of building aggregates.

Electrical Concrete Spun Pole Production Line Machine ...

2.Main constituent part---prestressed concrete pole SPINING MACHINE . Overview of Concrete Spun Pole Spinning Machine . Centrifugal spinning machine for prestressed spun concrete electrical pole is a kind of mold equipment, which is used for producing reinforced concrete poles and other cement products with a variety of different diameter and length.

More

IS 5613 | Electrical Notes & Articles

Abstract of IS: 5613 (Part 1, 2, 3) 1) Overhead Line Pole Foundation hole should be drilled in the ground with the use of earth-augers. ... Abstract of IS: 5613 (Part 1, 2, 3) 1) ... a bend of 10" to 30', either double cross arms or disc insulators should be used for HT lines up to 11 kV. For low and medium voltage line, shackle insulators ...

More

Prestressed Concrete Spun Electric Wire Pole Making ...

Prestressed Concrete Spun Electric Wire Pole Making Machine/concrete Pole Making Machine Production Line, Find Complete Details about Prestressed Concrete Spun Electric Wire Pole Making Machine/concrete Pole Making Machine Production Line,Electrical Wire Making Machine,Electrical Wire Making Machine,Electrical Wire Making Machine from Other Machinery & Industry Equipment …

More

UNITED STATES DEPARTMENT OF AGRICULTURE Rural …

UNITED STATES DEPARTMENT OF AGRICULTURE . Rural Development Utilities Programs . BULLETIN 1724E-206 . ... Specification for Spun, Prestressed Concrete Poles and Concrete Pole Structures " issued July, 2008. ... ASCE Guidelines for Electrical Transmission Line Structural

More

Prestressed concrete poles - concreteconstruction.net

s u p p o r t street lights, electric power lines, antenna m a s t s, and ove r head power lines for electric tra i n s. In ... most spun-cast poles have a uniform taper from top to bottom. The taper usually ranges from 0.15 to 0.18 inch per foot. Vi e r endeel poles (named for Belgian engineer, M. ...

More

Technical Specification for 33KV lines ( New & Up-rating ...

Technical Specification for 33KV lines ( New & Up-rating ) - 6 - Distance above highest flood level of non-navigable rivers. Refer to the Navigation Authority for clearances over navigable rivers. 5.3.1. Adjacent or Over Buildings Where bare 33kV overhead lines passes above or adjacent to any building or part of a building it shall

More

Utility pole - Wikipedia

A utility pole is a column or post used to support overhead power lines and various other public utilities, such as electrical cable, fiber optic cable, and related equipment such as transformers and street lights.It can be referred to as a transmission pole, telephone pole, telecommunication pole, power pole, hydro pole, telegraph pole, or telegraph post, depending on its application.

More

Home []

These spun poles we are offering are highly demanded for various electrical installation as durable poles for supporting the lines. Our spun poles are robust and finely fabricated using modern technology by our highly skilled personnel.

More

PC SPUN HOLLOW POLES & MOULDS - alibaba.com

RK Constructors is a company involved in manufacturing of a vide range of pre-cast/Prestressed concrete products, moulds and machinery including : Prestressed Concrete Spun Poles, HT & LT Prestressed Concrete poles and concrete blocks for buildings. We are the pioneers to design & develop this product in Pakistan & probably the only company in ...

More

Spun Concrete Transmission Poles HBL

HBL Power Systems Limited offers state-of-the-art technology Precast Pre-stressed Spun Concrete Poles for Power ... We produce spun concrete transmission poles that offer best utility and value for money. ... 11 190 337 50 900 350 11/33 KV lines 11/33 KV lines 11/33 KV lines 11-190-350 11-230-500 11 230 377 50 1080 500 11/33 KV lines 357 404 350

More

Safe Clearances for Overhead Power Lines - The Spruce

Safe Clearances for Overhead Power Lines. By Timothy Thiele. Updated 01/12/19. Pin Share Email P. Eoche/Getty Images. ... Operators should take time to look over the area before extending the boom and should stay at least 30 feet from all power lines and power poles.

More

Valmont Utility - Official Site

Spun Concrete Poles. Water, salt, coastal air, fog, mist, erosion, high winds, hot or corrosive soils, swampy environments and fire are just a few of the conditions that wreak havoc on most transmission poles—but not spun concrete.

More

Rates of various Line materials and Labour charges used in ...

Pre-Stressed Tubular Spun Pole 11M Long Nos 15800 2084 Double Pole Structure complete including 5 Kg, 8SWG, GI Wire for Structure Grounding ... Providing guarding between HT & LT line. (Including labour fixing of necessary cross arms) Mtr 63 533 (each upto a span of 40 mtrs)

More

Prestressed Concrete Poles| Concrete Construction Magazine ...

First designed and constructed by French engineer Freyssinet in the middle 1930s, prestressed concrete poles are used today worldwide for flag poles, sign poles, telephone poles, telegraph poles, and poles that support street lights, electric power lines, antenna masts, and overhead power lines for electric …

More

Prestressed Concrete Transmission Pole Structures | ASCE

Prestressed Concrete Transmission Pole Structures: Recommended Practice for Design and Installation is a complete engineering reference on static-cast and spun-cast prestressed concrete poles for electric distribution and transmission power lines. This Manual of Practice contains critical information for all aspects of a prestressed concrete ...

More

Prestressed Concrete Transmission Pole Structures | Books

Prestressed Concrete Transmission Pole Structures: Recommended Practice for Design and Installation is a complete engineering reference on static-cast and spun-cast prestressed concrete poles for electric distribution and transmission power lines. This Manual of Practice contains critical information for all aspects of a prestressed concrete ...

More

EASTERN POWER DISTRIBUTION COMPANY OF A.P.LIMITED ...

Sl. No. Description Page No. A ABSTRACT of rates of 33 KV / 11 KV / LT Lines 1 B Rates for CENTRALIZED MATERIALS 2 - 11 C Cost Data for Hilly and Tribal areas as adopted by Irrigation Department in the State 12 1 33 KV Line over 9.1 Mts. PSCC Poles at 105 Mts.Span WL 280 Kgs 13 2 33 KV Line over 9.1 Mts. PSCC Poles at 80 Mts.Span WL 280 Kgs 14 3 11 KV Line over 8 Mts. PSCC Poles …

More

Electric Poles | Electrical4U

The concrete electric pole is made of cement concrete. To increase the strength, we use iron bars or rods reinforcement in the concrete. For earthing purpose, we place a copper strip of size 25mm × 3mm inside the pole during concreting, or we keep a hollow channel in the pole for inserting the earthing wire.

More

Stresscrete Group - Home

StressCrete's spun concrete poles are the ideal utility poles for power distribution and transmission applications. Available in overall lengths up to 118' and delivered with a lifetime product warranty, StressCrete's spun concrete poles are durable and reliable, offering many advantages over other materials in the marketplace.

More

pre-stressed concrete spun electric pole/pile steel moulds ...

Pre-stressed Concrete Spun Electric Pole/pile Steel Moulds For The Production Line Of Electric Pole/pile, Find Complete Details about Pre-stressed Concrete Spun Electric Pole/pile Steel Moulds For The Production Line Of Electric Pole/pile,Pre-stressed Spun Pole Mould,Concrete Electric Pole Making Mould,Steel Moulds For Precast Concrete from Other Machinery & Industry Equipment Supplier or ...

More

Insulators used in overhead power lines | electricaleasy.com

Of course, the power line won't even work in that case! Hence, overhead power lines are always supported on insulators mounted on their support poles/towers. Overhead line insulators should have the following properties: high mechanical strength in order to withstand the conductor load, wind load etc.

More

Span Length & Pole Height - Energize Eastside EIS

Span Length & Pole Height Span length and pole height are two elements that PSE engineers examined when designing the proposed 230-kilovolt (kV) transmission line for the Eastside. Span length is the distance between each pole. This dimension is directly correlated with the number of poles that will be installed along a corridor.

More

Difference between HT and LT lines | Physics Forums

Jun 09, 2009· Difference between HT and LT lines Jun 8, 2009 #1. i.mehrzad. ... I have assumed that the power lines that carry a lot of current are the ones that contribute to high tension and the compliment being low tension. Is this a safe assumption, cause i don't find a definition for the two.

More

What is the difference between HT and LT Line? - Quora

What is the difference between HT and LT Line? Update Cancel. Answer Wiki. 10 Answers. Ananda Krishnan, B.Tech Electrical and Electronics Engineering, Visvesvaraya Technological University (2016) ... What is the difference between LT & HT power lines from their "applications" perspective?

More

MANUFACTURE OF PRE STRESSED TUBULAR SPUN CONCRETE POLE …

2.manufacture of pre stressed tubular spun concrete pole of 11 metre long. INTRODUCTION Wooden,steel and concrete poles were used for power distribution lines since nineteenth century,. The first pole used was wooden pole and addition to it steel tubular poles and S.M rail pole were in used.

More

Induscrete

Spun Concrete Poles LT cement poles Cement poles HT cement poles Manufacturer of Spun Poles Spun Poles Hollow Poles Poles Electric poles Cheap Poles. ... which have supplied over 5,00,000 11 meter and 9.5 meter poles for 11 KV and 440 Volt Lines to WAPDA and other private Organizations in the last 25 years. Since then it has sucessfully ...

More

SPUN PRE-STRESSED CONCRETE POLES: ALTERNATIVE TO …

spun concrete poles for 33-kV and 132-kV overhead lines in Oman, with extreme conditions of temperatures up to 60° C, sandstorms, termites, fire, and sun. The customer Petroleum Development Oman required a high-quality, reliable pole with a life span of 50+ years. These spun-concrete poles have been in use for three years and have successfully ...

More

Pole Line Construction 3: Erecting Poles & Attaching ...

May 11, 2016· A utility pole is a column or post used to support overhead power lines and various other public utilities, such as cable, fibre optic cable, and related equipment such as transformers and street ...

More

What is the size of the pole in the electricity distribution

What is the size of the pole in the electricity distribution ? ... power lines, electrical substations and pole-mounted transformers, low-voltage (less than 1000 V) distribution wiring and ...

More

Types of Electric Poles in Overhead Transmission Lines

The line supports used for transmission and distribution of electric power are of various types including wooden poles, steel poles, R.C.C. poles and lattice steel towers.The choice of supporting structure for a particular case depends upon the line span, X-sectional area, line voltage, cost and local conditions.

More